Control4 Wireless Thermostat Installation Guide 2
Sample Wiring Configurations
WARNING! Do not install LINE VOLTAGE wires to a LOW
VOLTAGE wire.
IMPORTANT! When utilizing power stealing, we recommend
installing the included 270 Ohm bypass resistor on the HVAC
system to minimize any potential side-effects. For additional
information on power stealing and installing the bypass resistor, visit
control4.com.
IMPORTANT! Do not install any REMOTE TEMPERATURE
SENSORS to the TS terminals other than supported external
temperature sensors (Flush Mount Remote Temperature Sensor,
Aprilaire™ Model 8051; or Duct/Outdoor Remote Temperature
Sensor, Aprilaire Model 8052). For installation instructions, see
Aprilaire documentation.
IMPORTANT! Install the U-shaped Terminal jumper wire between
RC and RH for a single stage system.
Wiring Connections
Warranty
For complete warranty information, including details on consumer legal rights as well as warranty
exclusions, visit www.control4.com/warranty.
About this Document
United States Patents Pending. Copyright © 2004-2006 Control4 Corporation. Control4 and the
Control4 logo are registered trademarks of Control4 Corporation. All trademarks are properties of
their respective owners.
Part Number: 21-0170 Rev C (3)
Terminal Description
RH 24VAC power for heating — connect to low voltage heating system
transformer. (See Note 1 below.)
RC 24VAC power for cooling — connect to low voltage cooling system
transformer. (See Note 1 below.)
B Conventional — heat damper control
Heat Pump — heat changeover valve
G Fan Relay
Y1 Conventional — air conditioner compressor
Heat Pump — primary stage relay
Y2 Conventional — 2nd stage compressor
Heat Pump — 2nd stage relay
W1 Conventional — heat relay
Heat Pump - auxiliary heat relay
W2 Conventional — 2nd stage heat relay
Heat Pump — not used
O Conventional — cool damper control
Heat Pump — cool changeover valve
TS Remote sensor (optional accessory)
TS/C Remote sensor (optional accessory)
Common wire return for dedicated power supply.
Note 1: Install the U-shaped Terminal jumper wire provided between RC and RH for
a single stage system.
Note 2: When connecting the common wire, ensure that power stealing is disabled
as described in step 14.